Florida Energy Code Component Comparisons
The following Table is a simple comparison on the net effect of changing one component on the Central Baseline house on the e-ratio. The software used was the current code compliance software (FlaRES 2004 v.4.50). As each house will be different, the table is a broad overview of component changes that could be expected and is not intended to reflect the actual effect on any one house with the exception of the example Central Region Baseline house in the software. Actual results may vary and may be affected by the law of diminishing returns when changing multiple components.
Component | Baseline | Measure Change | E-ratio |
Ceiling Insulation |
R30 |
R19 |
1.03 |
Ceiling Insulation |
R30 |
R38 |
.99 |
Ceiling Insulation/w Radiant Barrier |
R30 |
R19/RB |
.98 |
Ceiling Insulation/w Radiant Barrier |
R30 |
R30/RB |
.96 |
Windows |
Double, U-Factor=.75 SHGC=.4 |
Double, U-Factor=.87 SHGC=.55 (Metal Frame) |
1.03 |
Windows |
Double, U-Factor=.75 SHGC=.4 |
Double, U-Factor=.35 SHGC=.35 (Wood or Vinyl Frame) |
.95 |
Windows |
Double, U-Factor=.75 SHGC=.4 |
Single, Clear |
1.15 |
Windows |
Double, U-Factor=.75 SHGC=.4 |
Single, Tint |
1.11 |
Cooling |
SEER 13 |
SEER 14 |
.97 |
Cooling |
SEER 13 |
SEER 15 |
.94 |
Cooling |
SEER 13 |
SEER 16 |
.91 |
Ceiling Fan Credit |
N/A |
Yes |
.98 |
Programmable Thermostat |
N/A |
Yes |
.97 |
Heating |
Electric Heat Pump 7.7 HSPF |
Electric Resistance |
1.18 |
Heating |
Electric Heat Pump 7.7 HSPF |
Electric Heat Pump 8.4 HSPF |
.99 |
Ducts |
Air handler in Garage Supply and Returns in Unconditioned Space |
Air handler in Interior Supply and Returns in Unconditioned Space |
.94 |
Ducts |
Air handler in Garage Supply and Returns in Unconditioned Space |
Air handler in Attic Supply and Returns in Unconditioned Space |
1.06 |
Ducts |
Air handler in Garage Supply and Returns in Unconditioned Space |
Air handler in Interior Supply and Returns in Conditioned Space |
.90 |
Factory Sealed Air Handler |
N/A |
Yes |
.97 |
Leak Free Duct Credit |
N/A |
Yes |
.92 |
Hot Water |
Electric Resistance EF .92 |
Electric Resistance EF .94 |
.99 |
Hot Water |
Electric Resistance EF .92 |
Solar with Tank EF. 2.9 |
.74 |
Heat Recovery (AC) |
N/A |
Yes |
.94 |
Heat Recovery (HP) |
N/A |
Yes |
.92 |